Technical Specifications

Operating Temperature
0-60 Degrees C
__________________________________________

Temperature Resolution
0.000001 Degrees C
_________________________________________________

Repeatability
0.1% RSD
_________________________________________________

Resolution
0.001 (MJ/Kg)
_________________________________________________

Results per hour
10 sampes per hour using two vessels
__________________________________________

Power
90 - 260 VAC

Features

  • Easy to maintain, self system test for technicians
  • Compact size - able to fit more systems into a standard laboratory
  • Fully automatic operation - temperature readings and calculations are done for you
  • Possible to network up to 7 calorimeters
  • Rapid and accurate determinations
  • 10 samples per hour using the CAL2k-2 Cooler and 2 vessels
  • Isothermal design using a waterless patented vessel (no bucket, spillage or measuring)
  • Large memory for storing more than 2000 determinations, including operating conditions and user statistics
  • Automatic correction for firing wire, cotton, spikes etc
  • Fully automatic calibration, with 10 stored calibrations per vessel for standard deviation
  • Calibrated sensors built into vessel wall
  • Can use spiking for hard to combust samples
  • Intelligent "SMART" vessel with fault diagnostics and calorific processor
  • Vessels are pre-programmed for 5000 determination cycles before inspection
  • Adjustable firing limits set per vessel
  • High and low mass limits
  • Determination cycle adjustment
  • Other features include user, group and sample ID
  • CE Certified
  • Precise and reproducible determination of gross calorific values according to ISO 1928, DIN 51900 and BS1016:105

Software Features

  • User controlled access for vital and routine operations
  • Automatic results retrieval for selected and formatted data
  • Weigh station operation
  • Calorimeter and vessel setup
  • Calibration management
  • Service and maintenance routines
  • Filing, printing and other operator functions, including data export to common formats
  • Real time graphical temperature display
  • Network status display
  • Grouped sample determinations and analysis

Complete CAL2k System

Complete system consists of the following:
CAL2k-1        Calorimeter
CAL2k-1-KT   Calorimeter Installation Kit
CAL2k-2        Cooler
CAL2k-2-KT   Cooler Installation Kit
CAL2k-3        Filling Station
CAL2k-3-KT   Filling Station Installation Kit
CAL2k-4        Vessel
CAL2k-4-KT   Vessel Installation Kit

 

Optional Extras (Recommended or Required):

CAL2K-PCS       CAL2K Windows Operating Software on CD
CAL2K-PCC       PC Cable (required for software)
CAL2k-5           Docking Station
CAL2k-CIC        CAL2K Interconnection Cable (Required only when Networking of units)
REGULATOR       High Pressure Oxygen Regulator (Required and MUST be supplied before installation)

It is important to note that a High Pressure Oxygen Regulator capable of filling the vessel to 3Mpa (3000Kpa, 30 bar, 30 atm) is required and must be available/supplied prior to installation of the unit.

Items to Source Locally

Balance (Recommended Satorius Balance CP64 or equivalent)
Water Tap Connection
PC with Windows 98/2000/XP/NT4.0 Installed (Required only if running software - a PC is not required to operate the unit)

Contact Us



CAL2k and its associates disclaim all liability for any loss, damage, injury or expense however caused, arising from the use of or reliance upon, in any manner, the information provided through this service.

Copyright 2003 Digital Data Systems Pty Ltd.
DDS


Contact the Webmaster should you have any queries, problems