Technical
Specifications
Operating Temperature 0-60 Degrees C __________________________________________
Temperature Resolution 0.000001 Degrees C _________________________________________________
Repeatability 0.1% RSD _________________________________________________
Resolution 0.001 (MJ/Kg) _________________________________________________
Results per hour 10 sampes per hour using two vessels __________________________________________
Power 90 - 260 VAC
Features
- Easy to maintain, self system test for
technicians
- Compact size - able to fit more systems into a
standard laboratory
- Fully automatic operation - temperature readings
and calculations are done for you
- Possible to network up to 7
calorimeters
- Rapid and accurate determinations
- 10
samples per hour using the CAL2k-2 Cooler and 2
vessels
- Isothermal design using a waterless patented
vessel (no bucket, spillage or measuring)
- Large memory for storing more than 2000
determinations, including operating conditions and user statistics
- Automatic correction for firing wire, cotton,
spikes etc
- Fully automatic calibration, with 10 stored
calibrations per vessel for standard deviation
- Calibrated sensors built into vessel
wall
- Can use spiking for hard to combust
samples
- Intelligent "SMART" vessel with fault
diagnostics and calorific processor
- Vessels are pre-programmed for 5000
determination cycles before inspection
- Adjustable firing limits set per
vessel
- High and low mass limits
- Determination cycle adjustment
- Other features include user, group and sample
ID
- CE Certified
- Precise and reproducible determination of gross
calorific values according to ISO 1928, DIN 51900 and
BS1016:105
Software Features
- User controlled access for vital and routine
operations
- Automatic results retrieval for selected and
formatted data
- Weigh station operation
- Calorimeter and vessel setup
- Calibration management
- Service and maintenance routines
- Filing, printing and other operator functions,
including data export to common formats
- Real time graphical temperature
display
- Network status display
- Grouped sample determinations and
analysis
Complete CAL2k System

Complete system consists of the
following: CAL2k-1
Calorimeter CAL2k-1-KT Calorimeter Installation
Kit CAL2k-2
Cooler CAL2k-2-KT Cooler Installation
Kit CAL2k-3 Filling
Station CAL2k-3-KT Filling Station Installation
Kit CAL2k-4
Vessel CAL2k-4-KT Vessel Installation
Kit
Optional Extras (Recommended or
Required): CAL2K-PCS CAL2K Windows
Operating Software on
CD CAL2K-PCC PC Cable (required for
software) CAL2k-5
Docking Station CAL2k-CIC CAL2K
Interconnection Cable (Required only when Networking of
units) REGULATOR High Pressure Oxygen
Regulator (Required and MUST be supplied before installation)
It is
important to note that a High Pressure Oxygen
Regulator capable of filling the vessel to 3Mpa (3000Kpa, 30 bar, 30
atm) is required and must be available/supplied prior to installation
of the unit.
Items to
Source Locally
Balance (Recommended Satorius Balance CP64 or
equivalent) Water Tap Connection PC with Windows 98/2000/XP/NT4.0
Installed (Required only if running software - a PC is not required to operate
the unit)
CAL2k and its associates disclaim all liability for any loss, damage, injury
or expense however caused, arising from the use of or reliance upon, in
any manner, the information provided through this service. |
|
Copyright
2003 Digital Data Systems Pty Ltd.
 |
Contact the Webmaster
should you
have any queries, problems or suggestions regarding the
CAL2k
Website.
|
|