Advanced Bomb Calorimeters - Manufacturing Superb Calorimeter for today's Analytical Needs.

 

Bomb Vessel

Purchase Bomb Vessel

CAL2K Bomb Calorimeter Vessel


CAL2K Bomb Calorimeter Vessel

CAL2K Bomb Calorimeter Vessel

The DDS Bomb vessel is unique in that it is the first of its kind and has the following features:


  • The vessel is smaller than conventional vessels, which results in a smaller heat capacity. Special attention has been given to a thermally balanced vessel design which has been achieved using computer aided design (CAD) and computer simulation of heat transfer characteristics.
  • The vessel has an oxygen volume of 0.22 litres (220ml), which allows for a 0,5gr coal sample at approximately 30MJ/Kg. The temperature sensors are located cylindrically within the vessel walls at eight places.
  • The approximate temperature rise of the vessel after burning of 0,5gr benzoic acid is 9 degrees C. Practical tests have shown that up to 0.8gr of benzoic acid can be burnt without affecting the accuracy. Oxygen starvation affects the results with higher charges.
  • The vessel is "smart" with a microprocessor built into the base of the unit. All the information pertinent to a vessel is stored permanently inside the vessel i.e. vessel number, calibration, number of firings, date of last reconditioning etc.
  • The vessel PCB is only powered up when it is placed in the calorimeter. The consequences of the vessel memory is that any vessel can run in any calorimeter without a new calibration.
  • The vessel memory can only be accessed from the PC. The electronics and sensors are vacuum epoxy impregnated to prevent physical damage as well as moisture from entering the electronics.
  • The firing wire is semi-permanent and only needs to be replaced when the wire is burnt or damaged.


CAL2k-4 Bomb Vessel Improvements:


  • The electronics and sensors are built inside the vessel. The vessel is placed inside the calorimeter and is "docked" in the calorimeter for supervision. The result is a faster more stable temperature reading. The vessel temperature is measured by 8 sensors. The vessels are vacuum expoxy sealed, and no adjustment or maintenance is required.
  • The vessel can be operated over a wider temperature range (+10 degrees to +50 degrees C) but it is advised that the vessels starting temperature is within 12 degrees of the ambient (room) temperature.

 

Using the CAL2K-4 Bomb Vessel

Using the CAL2K-4 Bomb Vessel