WELCOME TO CAL2K
Advanced Bomb Calorimeters - Manufacturing Superb Calorimeter for today's Analytical Needs.
E2K CALORIMETER
|
Digital Data Systems has upgraded the e2k bomb calorimeter system. The system now has full menu control. The system can operate fully without a PC and results can be printed directly to a RS232 printer. PC and software is optional, however the system is now fully operational without software. All menu functions can be done via the calorimeter. We call the new upgraded version - Version 2. The system is middle of the range and available in a variety of system options to suit different customer options.
![]() |
![]() |
![]() |
| The Calorimeter | The Cooler | The Filling Station |
Specifications
Technical Specifications:
|
E2K Manuals
View the E2K Operating Manual V3.4
View the E2K Maintenance Manual V3
Instruction Videos
Using the E2K Calorimeter System
View the E2K Brochure
View CAL2K Product Catalogue
E2K FEATURES
Features:
- Intelligent operation support
- Very fast operation due to improved software
- Easy to maintain, self test for technicians and operators
- Compact size
- Operation can be configured to suit every laboratory
- Rapid and accurate determinations
- Capable of doing 10 CV samples per hour using a CAL2k-2 Cooler and 2 vessels
- Isothermal design using a waterless patented vessel (no bucket, spillage or measuring)
- Large memory for storing +1000 determinations
- Manual or automatic mass entry through keyboard or balance interface
- Easy to read LCD display in one standard (English) language and one alternative language
- Fully automatic calibration in BTU, CAL, MJ/Kg
- Uses the CAL2k-4 intelligent vessel with fault diagnostics and microprocessors
- Interfaces to standard PS2 computer keyboard
- Acoustical warning for operator convenience
- Extra 8 digit group identification can be used as a sample id
- Print results directly without PC on stadard 80 column serial printer with RS232 port
- Alternative language switch at rear of unit
- Real-time clock with one week back up
- Precise and reproducible determination of gross calorific values according to ISO 1928, DIN 51900 and BS1016:105
Software Features:
- User controlled access for setting vital parameters once
- Automatic result retrieval for selected and formatted data
- Filing printing and other operator functions, including data export to common formats
- Real time graphical vessel temperature display
- Grouped sample determinations and analysis
- Alternative language management
- English Windows Operating software version only
- Real time clock setting
- Vessel data viewing
- High speed communication for fast data retrieval
|
|
|
THE COMPLETE E2K SYSTEM AND EXTRAS
Complete e2K System:

Complete Standard System consists of the following :
- E2K - Calorimeter
- E2K-KT Calorimeter Installation Kit
- CAL2K-2 Cooler
- CAL2K-2-KT Cooler Installation Kit
- CAL2K-3 Filling Station
- CAL2K-4-KT Filling Station Installation Kit
- CAL2K-4 Vessel
- CAL2K-4-KT Vessel Installation Kit
The e2K is also available in the following configurations:

Minimum System consists of the following :
- 1 x E2K Calorimeter
- 1 x E2K Calorimeter Installation Kit
- 1 x CAL2K-3 Filling Station
- 1 x CAL2K-3 Filling Station Installation Kit
- 1 x CAL2K-4 Vessel
- 1 x CAL2K-4 Vessel Installation Kit
The above option does not include the CAL2k-2 Cooler,
reducing the number of samples per hour.

Elite System consists of the following :
- 1 x E2K Calorimeter
- 1 x E2K Calorimeter Installation Kit
- 1 x CAL2K-2 Cooler
- 1 x CAL2K-2 Cooler Installation Kit
- 1 x CAL2K-3 Filling Station
- 1 x CAL2K-3 Filling Station Installation Kit
- 2 x CAL2K-4 Vessels
- 2 x CAL2K-4 Vessel Installation Kits
The above option includes the CAL2k-2 Cooler and includes 2 Vessels, increasing the number of samples per hour to 10.
Optional Extras:
- E2K-PCS - E2K Windows Operating Software on CD
- CAL2K-PCC - PC Cable (required for software)
- REGULATOR - High Pressure Oxygen Regulator (Required and MUST be supplied before installation)
It is important to note that a High Pressure Oxygen Regulator capable of filling the vessel to 3Mpa (3000Kpa, 30 bar, 30 atm) is required and must be available/supplied prior to installation of the unit.
Items to source locally:
- Balance (Recommended Satorius Balance CP64 or equivalent)
- Water Tap Connection (if using cooler)
- PC with Windows 98/2000/XP/NT4.0 Installed (Required only if running software - a PC is not required to operate the unit)
Accessories
|
|
The VesselThe CAL2K-4 vessel is the first of its kind and is the heart of the CAL2K system. Its sophisticated design allows the temperature to be measured to five decimal places in degrees Celsius. The vessel is an intelligent (SMART) vessel with a microprocessor built into its base. The vessel is capable of : firing counts, identification, memory and reconditioning data.
The vessel is the combustion chamber. It is made of stainless steel and tested up to a pressure of 300 atmospheres (4200 psi). |
|
|
The Filling StationThe filling station is designed to fill the vessel with oxygen to 3Mpa. The filling rate is controlled so as not to disrupt the sample in the crucible. The Filling Station is extremely easy to operate and requires minimal adjustments and maintenance. |
|
|
The CoolerThe unit is designed to reduce the temperature of a recently fired vessel, obtained from the calorimeter, to ambient temperature in 2-3 minutes. Solid state cooling is used and the hot junction of the peltier elements is cooled by a continuous trickle of water from the main water supply. |
|
|
Air Cooler (Fan)The e2k calorimeter can be used with a Fan Air Cooler, the e2k-FAN, however this is only applicable with the minimum system option. It takes approximately 20 minutes for the e2k Fan Air Cooler to bring the vessel temperature back to ambient temperature. |
Downloads
DOWNLOAD THE E2K BROCHURE 2013
Download the E2K Operating Manual