Technical
Specifications
Operating Temperature 0 - 60
Degrees
C ________________________________________
Temperature
Resolution 0.000001 Degrees
C ________________________________________
Repeatability 0-1%
RSD ________________________________________
Resolution 0.001
(MJ/Kg) ________________________________________
Results per hour 1 sample per
hour / 8 per
day ________________________________________
Power 90-260VAC
Features
-
Ideal for low volume application up
to 1 sample per hour with one vessel. Maximum 8 samples per day
-
No water required
-
Inexpensive
-
No operator attention required
during analysis, the LCD display prompts the operator and displays faults and
progress
-
Uses the proven CAL2k-4 Intelligent
vessel
-
Small and compact
-
Uses a standard PC keyboard
(PS2)
-
Result retrieval connected to a PC,
using the supplied Windows Operating Software
-
Stores 1024 results and other
variables
-
Sample identification is settable
and self-incrementing
-
Vessel temperature can "stream" to a
PC for user spreadsheet analysis
-
Factory setup for standard
operation, however some values can be changed via the keyboard
-
Can use "spiking" for hard to
combust samples
-
Can connect directly to balance for
mass entry, or the mass can be entered via the keyboard
-
Built in diagnostic, which is ideal
for first hand diagnostic
-
Vessels are pre-programmed for 5000
determination cycles before inspection
-
External power supply for 9 Volts,
100mA is supplied
-
Works in BTU/lb, Calories/grams or
MJ/Kg
Complete ECO
System

Complete system consists of the
following: ECO
Calorimeter ECO-KT
Calorimeter Installation
Kit CAL2k-3 Filling
Station CAL2k-3-KT Filling Station
Kit CAL2k-4
Vessel CAL2k-4-KT Vessel Installation
Kit
Optional Extras (Recommended or
Required):
REGULATOR High Pressure
Oxygen Regulator (Required and MUST be supplied before installation)
It is
important tonote that a High Pressure Oxygen Regulator
capable of filling the vessel to3Mpa (3000Kpa, 30
bar, 30 atm) is required and must be available/supplied prior to
installation of the unit.
Items to Source Locally
Balance (Recommended Satorius Balance CP64 or
equivalent)
PC with Windows 98/2000/XP/NT4.0 Installed
(Required only if running software - a PC is not required to operate the
unit)
CAL2k and its associates disclaim all liability for any loss, damage, injury
or expense however caused, arising from the use of or reliance upon, in
any manner, the information provided through this service. |
|
Copyright
2003 Digital Data Systems Pty Ltd.
 |
Contact the Webmaster
should you
have any queries, problems or suggestions regarding the
CAL2k