Digital
Data Systems supplys both the accessories, spare parts and consumables for all 3
"dry" static jacket isothermal bomb calorimeter models. The consumables and
accessories are the same for all 3 models making it easier when ordering. Below
are the accessories required to run the bomb calorimeter systems, these are the
CAL2k-2 Cooler, CAL2k-3 Filling Station and the CAL2k-4 Vessel. Consumables such
as o-rings, firing wire, firing cotton, electrodes etc., are readily available
from
dds and our agents, please contact
us for a detailed list and pricing.
DDS is
proud to introduce our new certified Benzoic Acid tablets. We
are now offering certified tablets as part of our consumable list. The tablets
are sold in bottles of 50 x 0,5g tablets less than $25.00 per
bottle
. Please contact us or
your nearest agent should you wish to purchase these tablets. Benzoic Acid
is used for calibration and standardization of bomb calorimeter systems.

The CAL2k-2 Cooling unit is designed to reduce the
temperature of a recently fired vessel, obtained from the calorimeter, to
ambient temperature. Solid state cooling is used and the hot junction of the
peltier elements is cooled by a continous trickle from the mains water supply.
CAL2k-2
Cooler
CAL2k-2-KT Cooler Installation Kit
Kit
includes:
3 water pipe hose clamps, 1 cable, 10 meters of water pipe and a
mains cable

The filling station
is designed to fill the vessel with oxygen to 3000Kpa (3Mpa). The filling rate
is controlled so as not to distrub the sample inside the crucible. The filling
station is extremely easy to operate and requires minimal adjustments and
maintenance.
CAL2k-3
Filling Station
CAL2k-3-KT Filling
Station Installation Kit
Kit includes:
2 flow ajustors, 5 nozzle
o-rings, 2 high pressure pipes (1m), 1 oxygen regulator, 1 defiller cap,
1
handling hook

The CAL2k-4 Vessel is the first of its kind and is the heart of the
calorimeter system. Its sophisticated design allows the temperature to be
measured to five decimal places in degrees celsius. The vessel is an intelligent
(SMART) vessel with a microprocessor built into its base. The vessel is capable
of storing firing counts, identification, results, memory and reconditioning
data all it's memory.
CAL2k-4
Vessel
CAL2k-4-KT Vessel Installation
Kit
Kit includes:
1 centre electrode, 10 top & bottom o-rings, 5
lid o-rings, 1 outside electrode, firing wire and 1 deflector
plate
A supply of oxygen at a pressure of
3.0Mpa (30 bar) (3000Kpa) within 10 meters of the bomb calorimeter
system is required. A suitable pressure regulator must be supplied to allow for
this high pressure. DDS can supply a suitable regulator at an additional cost or
this item should be sourced locally by the agent or customer. However it is
important to note that this item is VITAL and
MUST be available/supplied before installation of the unit.
Without the high pressure regulator you will NOT be able to
operate the system.
CAL2k and its associates disclaim all liability for any loss, damage, injury
or expense however caused, arising from the use of or reliance upon, in
any manner, the information provided through this service. |
|
Copyright
2003 Digital Data Systems Pty Ltd.
 |
Contact the Webmaster
should you
have any queries, problems or suggestions regarding the
CAL2k
Website.
|